Sepolina Specs

Dimension Value Unit
External Dimensions
Housing - Length/Width/Height 120 / 108 / 138 Millimeters
Connector - Diameter/ Length (Range) 24 / 38 - 78 Millimeters
FreezeBlock Custom
Electrical
Electrical Rating 12 - 8.33 Volts - Amps
Power Consumption Full Load 0.1 KiloWatts
Electrical Connection 4 Pin Molex x2 + 6 Pin Pcie
Cooling
Cooling Capacity Rating 2 KiloWatts
Rated Output Temperature 20 Celcius

Disclaimer: Values represented above are subject to change. Detailed specifications are available upon request.

Alternative Cooling Methods

CRAC

Computer Room Air Conditioning (CRAC) : Cooling system based on bringing output airflow temperature to below ambient air temperatures, by exposing the input airflow to heat exchangers containing a  substance that is liquid at below zero temperatures.

crac
Dimension Value Unit
Electrical Rating 208/3/60hz - 129 Volts / Phase / Frequency - MCA Amps
Power Consumption Full Load 44.15 KiloWatts
Cooling Capacity Rating 98 KiloWatts
Rated Output Temperature 17 Celcius

Disclaimer: Values represented above are based on manufacturer specifications or estimations derived from listed specifications. Dataset is available upon request.

CRAH

Computer Room Air Handler (CRAH) : Cooling system based on removing heat from input airflow by exposure to a heat exchanger, with or without a secondary substance within the heat exchanger.

crah
Dimension Value Unit
Electrical Rating 208/3/60hz - 23 Volts / Phase / Frequency - MCA Amps
Power Consumption Full Load 7.87 KiloWatts
Cooling Capacity Rating 98 KiloWatts
Rated Output Temperature 20 Celcius

Disclaimer: Values represented above are based on manufacturer specifications or estimations derived from listed specifications. Dataset is available upon request.

Immersion Cooling

Immersion Cooling: Cooling system based on submerging heat producing components in a fluid that does not conduct electricity. The fluid is used to transfer heat away from submerged components and is then pumped to a heat exchanger or exposed to an evaporator coil with a fluid cooler than the immersion fluid; both methods are used to remove heat from the immersion fluid and the components submerged as well.

immersion
Dimension Value Unit
Electrical Rating 208/3/60hz - 17.85 Volts / Phase / Frequency - MCA Amps
Power Consumption Full Load 6.11 KiloWatts
Cooling Capacity Rating 98 KiloWatts
Rated Output Temperature 32 Celcius

Disclaimer: Values represented above are based on manufacturer specifications or estimations derived from listed specifications. Dataset is available upon request.

Water Chiller

Water Chiller: Cooling system based on exposing water to a substance within a heat exchanger that is liquid at below zero temperatures. This water is then distributed either directly to heat producing components or to a cooling system for the purpose of cooling heat producing components.

water_chiller
Dimension Value Unit
Electrical Rating 460/3/60hz - 65 Volts / Phase / Frequency - MCA Amps
Power Consumption Full Load 49.20 KiloWatts
Cooling Capacity Rating 98 KiloWatts
Rated Output Temperature 10 Celcius

Disclaimer: Values represented above are based on manufacturer specifications or estimations derived from listed specifications. Dataset is available upon request.